9513(NPIV enable)--fc2/2---- ---fc1/1(NP port)---9134---(fc1/10 host)
All the ports are in vsan 30
NPV switch 9134 config:
Make sure switch password and console access is there before you do this,
npv enable.
npv enable and set the port to NP mode
MDS9134-SJ# show run int fc1/1
version 3.2(1a)
interface fc1/1
port-license acquire
switchport mode NP
no shutdown
This port is upstream to NPIV enabled switch and
fc1/10 is where host is connected
MDS9134-SJ# show run int fc1/10
version 3.2(1a)
interface fc1/10
port-license acquire
switchport mode F
no shutdown
They both have to be in same vsan else
NPIV upstream not availabe error might be there.
sh npv internal errors
192) Event:E_DEBUG, length:186, at 683624 usecs after Fri Apr 25 16:17:04 2008
[102] npivp_mts_hdlr_fwd_internal_flogi_update(1165): Unable to match the fw
d response for internal FLOGI with any of the outstanding responses, ignoring th
e resp, error: fu unknown error
193) Event:E_DEBUG, length:136, at 652218 usecs after Fri Apr 25 16:17:04 2008
[112] E(1,fc1/1) Upstream Port VSAN(30) for this interface is different from
the local port VSAN(1)Failing this external interface: fc1/1
MDS9134-SJ# show npv flogi-table
--------------------------------------------------------------------------------
SERVER EXTERNAL
INTERFACE VSAN FCID PORT NAME NODE NAME INTERFAC
E
--------------------------------------------------------------------------------
fc1/10 1 0x0a0400 21:00:00:e0:8b:0b:38:0e 20:00:00:e0:8b:0b:38:0e fc1/1
Total number of flogi = 1.
MDS9134-SJ# show npv status
npiv is enabled
External Interfaces:
====================
Interface: fc1/1, VSAN: 1, FCID: 0x0a000d, State: Up
Number of External Interfaces: 1
Server Interfaces:
==================
Interface: fc1/2, State: Pre-Initialized
Interface: fc1/10, VSAN: 1, State: Up
Number of Server Interfaces: 2
Eari
Earlier Error
MDS9134-SJ(config-if)# do show int fc1/10
fc1/10 is down (NPV upstream port not available)
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:0a:00:0d:ec:51:05:40
Admin port mode is F
snmp link state traps are enabled
Port vsan is 30
Ve
Becasuse upstream port fc1/1 is in vsan 1 and fc1/10 is vsan 30..?
What if upstream port in vsan 30 but remote switch with npiv does
not have vsan 30.
MDS9134-SJ# show npv sta
npiv is enabled
External Interfaces:
====================
Interface: fc1/1, State: Failed(Mismatch in VSAN for this upstream port)
Number of External Interfaces: 1
Server Interfaces:
==================
Interface: fc1/2, State: Waiting for External Interface
Interface: fc1/10, State: Waiting for External Interface
Number of Server Interfaces: 2
Created vsan 30 on 9513
then
MDS9134-SJ# show npv sta
npiv is enabled
External Interfaces:
====================
Interface: fc1/1, VSAN: 30, FCID: 0xa00000, State: Up
Number of External Interfaces: 1
Server Interfaces:
==================
Interface: fc1/2, State: Waiting for External Interface
Interface: fc1/10, VSAN: 30, State: Up
Number of Server Interfaces: 2
ee
No flogi commands are there...
Commands
MDS9134-SJ# show npv internal event- flogi-fsm interface fc1/10
7) FSM:
25 16:50:55 2008
Previous state: [NPIVP_FLOGI_ST_WAIT_ON_FCID_ADD]
Triggered event: [NPIVP_FLOGI_EV_FCID_UPDATE_SUCCESS_RESP]
Next state: [NPIVP_FLOGI_ST_STEADY_STATE]
8) FSM:
25 16:50:55 2008
Previous state: [NPIVP_FLOGI_ST_STEADY_STATE]
Triggered event: [NPIVP_FLOGI_EV_SEND_FLOGI_ACC]
Next state: [FSM_ST_NO_CHANGE]
MDS9134-SJ# show npv internal event- ext-if-fsm int fc1/1\
497) FSM:
2008
Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION]
Triggered event: [NPIVP_EXT_IF_EV_NS_RSNN_RESPONSE_SUCCESSFUL]
Next state: [FSM_ST_NO_CHANGE]
498) FSM:
2008
Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION]
Triggered event: [NPIVP_EXT_IF_EV_NS_RSPN_RESPONSE]
Next state: [FSM_ST_NO_CHANGE]
499) FSM:
2008
Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION]
Triggered event: [NPIVP_EXT_IF_EV_NS_RSPN_RESPONSE_SUCCESSFUL]
Next state: [FSM_ST_NO_CHANGE]
500) FSM:
2008
Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION]
Triggered event: [NPIVP_EXT_IF_EV_VALIDATE_INT_FLOGI_ACC_SUCCESS]
Next state: [NPIVP_EXT_IF_ST_UP]
Curr state: [NPIVP_EXT_IF_ST_UP]
NPIV switch config and commands:
MDS9513-83-SJ(config)# do show run int fc2/2
version 3.2(2c)
interface fc2/2
no shutdown
switchport mode F
MDS9513-83-SJ(config)# do show int fc2/2
fc2/2 is up
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:42:00:0d:ec:2c:54:c0
Admin port mode is F
snmp link state traps are enabled
Port mode is F, FCID is 0xa00000
Port vsan is 30
Speed is 4 Gbps
Rate mode is dedicated
Transmit B2B Credit is 16
Receive B2B Credit is 16
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 128 bits/sec, 16 bytes/sec, 0 frames/sec
5 minutes output rate 104 bits/sec, 13 bytes/sec, 0 frames/sec
231 frames input, 22980 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
257 frames output, 19556 bytes
0 discards, 0 errors
5 input OLS, 5 LRR, 5 NOS, 0 loop inits
MDS9513-83-SJ(config)# do show flogi database interface fc2/2
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
---------------------------------------------------------------------------
fc2/2 30 0xa00000 20:01:00:0d:ec:51:05:40 20:1e:00:0d:ec:51:05:41
fc2/2 30 0xa00100 21:00:00:e0:8b:0b:38:0e 20:00:00:e0:8b:0b:38:0e
[Win_HBA0]
MDS9513-83-SJ# show fcns database npv NOde_wwn 20:1e:00:0d:ec:51:05:41
VSAN 30:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0xa00100 N 21:00:00:e0:8b:0b:38:0e (Qlogic) scsi-fcp:init
[Win_HBA0]
Total number of entries = 1
MDS9513-83-SJ# show flogi database details
---------------------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME FLAGS
---------------------------------------------------------------------------------------
fc2/1 5 0xbd0000 21:00:00:e0:8b:08:dd:22 20:00:00:e0:8b:08:dd:22 ADOP
fc2/2 30 0xa00000 20:01:00:0d:ec:51:05:40 20:1e:00:0d:ec:51:05:41
fc2/2 30 0xa00100 21:00:00:e0:8b:0b:38:0e 20:00:00:e0:8b:0b:38:0e AVDO
[Win_HBA0]
fc2/8 1 0x0a000c 50:06:01:68:88:02:90:ce 50:06:01:60:11:02:90:ce
fc2/10 777 0x490300 21:00:00:d0:b2:00:82:c0 20:00:00:d0:b2:00:82:c0 ADOP
fc2/11 777 0x490200 21:02:00:d0:b2:00:82:c0 20:02:00:d0:b2:00:82:c0 ADOP
fv4/1/1 1 0x0a0000 26:02:00:0d:ec:2c:54:c2 26:0b:00:0d:ec:2c:54:c2 P
fv4/1/2 1 0x0a0001 26:03:00:0d:ec:2c:54:c2 26:0c:00:0d:ec:2c:54:c2 P
fv4/2/1 1 0x0a0002 26:04:00:0d:ec:2c:54:c2 26:0d:00:0d:ec:2c:54:c2 P
fv4/2/2 1 0x0a0009 25:02:00:0d:ec:2c:54:c2 25:03:00:0d:ec:2c:54:c2 P
fv4/3/1 1 0x0a0003 26:05:00:0d:ec:2c:54:c2 26:0e:00:0d:ec:2c:54:c2 P
fv4/4/1 1 0x0a0004 26:06:00:0d:ec:2c:54:c2 26:0f:00:0d:ec:2c:54:c2 P
fv4/5/1 1 0x0a0005 26:07:00:0d:ec:2c:54:c2 26:10:00:0d:ec:2c:54:c2 P
fv4/6/1 1 0x0a0006 26:08:00:0d:ec:2c:54:c2 26:11:00:0d:ec:2c:54:c2 P
fv4/7/1 1 0x0a0007 26:09:00:0d:ec:2c:54:c2 26:12:00:0d:ec:2c:54:c2 P
fv4/8/1 1 0x0a0008 26:0a:00:0d:ec:2c:54:c2 26:13:00:0d:ec:2c:54:c2 P
Total number of flogi = 16.
FLAGS:
A area FCID allocation
L loop device
V FDISC
D the wwn matches the default OUI list
O the wwn matches the configured OUI list
P allocation was done based on the persistency table
--------------
MDS9513-83-SJ# show run | include npi
npiv enable
MDS9513-83-SJ# show fcns database npv
VSAN 30:
-------------------------------------------------------------------------------
NPV NODE-NAME NPV IP_ADDR NPV IF CORE SWITCH WWN CORE IF
-------------------------------------------------------------------------------
20:1e:00:0d:ec:51:05:41 172.16.33.23 fc1/1 20:00:00:0d:ec:2c:54:c0 fc2/2
172.16.33.23 is 9134 switch.
which has npv enabled
MDS9513-83-SJ# show fcns database npv de
------------------------------------------------------------
VSAN:30 NPV Node Name: 20:1e:00:0d:ec:51:05:41
------------------------------------------------------------
NPV Fabric Port-WWN :20:01:00:0d:ec:51:05:40
class :2,3
NPV IP Address :172.16.33.23
ipa :ff ff ff ff ff ff ff ff
fc4-types:fc4_features :npv
NPV Switch Name:Interface :MDS9134-SJ:fc1/1
port-type :NP
Core Switch fabric-port-wwn :20:42:00:0d:ec:2c:54:c0
permanent-port-wwn (vendor) :20:01:00:0d:ec:51:05:40 (Cisco)
Total number of entries = 1
======================================================================
No comments: